二手 罗德施瓦茨 R/S 矢量网络分析仪 ZVC 8GHZ
二手 罗德施瓦茨 R/S 矢量网络分析仪 ZVC 8GHZ
Rohde&Schwarz ZVC 8G网络分析仪罗德与施瓦茨20kHz-8GHz的详细介绍
Rohde&Schwarz ZVC 8G网络分析仪罗德与施瓦茨20kHz-8GHz
厂商名称:德国罗德与施瓦茨Rohde&Schwarz R&S
特点
·20kHz~8GHz频率范围
·高测量速度(<125μs/测量点)
·低固有噪声(-130dB)
·宽动态范围(>130dB)
·高频率分辨率(10μHz)
·校准时间短(<20s)
·有源彩色LCD(26cm)
技术指标
·Data only for 50Ω test sets.For 75Ω test sets and further details please refer to data sheet PD 757.1802.23.Unless otherwise stated,specifications apply to test ports PORT 1 and PORT2,a nominal source power of -10dBm at the test port and an IF bandwidth≤10kHz
·The arrow marks important data.
·Frequency range,measurement speed,dynamicrange
·Frequency range
·Without External Measurements option
·ZVRL,ZVRE,ZVR
·with passive test set 50Ω or 75Ω|9kHz to4Ghz
·with active test set 50Ω or 75Ω|300kHz to4GHz
·ZVCE,ZVC
·with active test set 50Ω|20kHz to 8GHz
·With External Measurement option
·ZVRL,ZVRE,ZVR|10Hz to 4Ghz
·ZVCE,ZVC|20kHz to 8Ghz
·Relative frequency ·deviation|<2*10^-6+1*10^-6/a
·Resolution|10μHz
·Measurement speed(above 2Mhz)
·Number of points|1 to 2001(selectable)
·Measurement time per point|IFbandwidth(IFBW)
3kHz
10kHz
26kHz
with systemerrorcorrection
<1.50μs
<460μs
<330μs
normalized
<530μs
<230μs
<190μs
FastMode
withsystemerror correction
-
-
<240μs
normalized
-
-
<125μs
·Dynamicrange(without system error correction)
·ZVRL,ZVRE,ZVR
·(models ZVRL and ZVRE:at IF bandwidth 10Hzvalues are reduced by 5dB)
IFbandwidth
With passivetest set 50Ω
10Hz
3kHz
10kHz
20kHz to20MHz
>65dB,
typ.>110dB
-
-
200kHz to20MHz
>110dB
>90dB
>85dB
20MHz to3Ghz
>120dB
>100dB
>95dB
3Ghz to4Ghz
>110dB
>90dB
>85dB
With activetest set 50Ω
300kHz to1Mhz
>107dB
>87dB
>82dB
1MHz to20MHz
>110dB
>90dB
>85dB
20MHz to3Ghz
>120dB
>100dB
>95dB
3Ghz to4Ghz
>110dB
>90dB
>85dB
With ExternalMeasurements option
50Hz to200kHz
>75dB
-
-
200kHzto20MHz
>110dB
>95dB
>90dB
20MHz to1Ghz
>130dB
>110dB
>105dB
1Ghz to3Ghz
>120dB
>100dB
>95dB
3Ghz to4Ghz
>110dB
>95dB
>90dB
·ZVCE,ZVC
·(mode ZVCE:at IF bandwidth 10Hz values arereduced by 5dB)
With active test set 50Ω
20kHz to200kHz
>60dB,
-
-
200kHzto20MHz
>100dB
>80dB
>75dB
20Mhz to3Ghz
>120dB
>100dB
>95dB
3Ghz to4Ghz
>110dB
>90dB
>85dB
4Ghz to6Ghz
>105dB
>85dB
>80dB
6Ghz to8Ghz
>100dB
>80dB
>75dB
WithExternal/Measurements option
20kHz to200kHz
>75dB
-
-
200kHz to20Mhz
>110dB
>95dB
>90dB
20MHz to1GHz
>130dB
>110dB
>105dB
1Ghz to3Ghz
>120dB
>100dB
>95dB
3Ghz to4Ghz
>110dB
>95dB
>90dB
4GHz to6GHz
>105dB
>90dB
>85dB
6Ghz to8GHz
>100dB
>85dB
>80dB
Stability ofmeasurement trace
per degree temperaturevariation
ZVRL,ZVRE,ZVR
<0.05dBor 0.4°
ZVCE,ZVC
<0.1 dB or1°
Measurementbandwidth
(IF bandwidthIFBW)
1Hz to 10kHz(half-decade steps)
and 26kHz(full)
·Measurementaccuracy
·The following data are validbetween 20℃ and 30℃ provided the instrument has reached thermal equilibrium (about 1 h after switch-on)and the tempera-ture has not varied by more than 1 degree after calibration.
·ZVRE and ZVR(bidirectional networkanalyzers)
·Accuracy of transmission measurementsafter full two-part system error cor-rection(TOSM)
·Specificaitons are based on a matched DUTand refer to a nominal source power of -10dBm at the test port.
·With test set 50Ω 300kHz to 4Ghz
at IF bandwidth 10Hz
·for+10dB to +3dB|<1dB or 6°
·for+3dB to -5dB|<0.2dB or 1°
·for -5dB to -60dB(passive|<0.05dB or0.4°
·for-5dB to -60dB(active)|0.2dB or 1°
·for+3dB to -40dB|typ.<0.025dB
·for-60dB to -70dB|<0.2dB or 1°
·for-70dB to -80dB(ZVRE)|<1dB or 6°
·for-70dB to -85dB(ZVR)|<1dB or 6°
·Accuracy of reflection measurements
·after system error correction (TOSM orfull one-port)
·Specificaitons are based on an isolationgDUT and refer to a nominal source powe
*您的姓名:
*联系手机:
固话电话:
E-mail:
所在单位:
需求数量: