产品说明Explain

公司简介Content


处理器CP701  横河
DCS培训资料:
  Auxiliary  Output  Values  (PV,  △PV,  MV,  △MV)辅助输出值
The  auxiliary  output  values  include  PV,  △PV,  MV  and△MV,  the  types  vary  with  the  function  block.  The  engineering  unit  and  scale  range  of  the  auxiliary  output  values  change  in  accordance  with  the  connected  destination  of  the  SUB  terminal.辅助输出值包括PV,  △PV,MV和△MV,类型随功能块而变化。辅助输出值的工程单位和范围随着辅助输出端的连接目标而变化。
?  If  the  connected  destination  is  a  process  I/O,  the  scale  range  and  engineering  unit  of  the  auxiliary  output  values  are  fixed  to  “0  to  100”  and  “%,”  respectively.  However,  this  rule  does  not  apply  if  the  connection  destination  is  a  Fieldbus  block.  如果连接目标是一个过程I/O,辅助输出的量程和工程单位被分别确定为0到100和%。如果连接目标是一个现场总线块时不采用这个规则。
?  When  the  connected  destination  is  a  function  block  and  auxiliary  output  is  the  process  variable  (PV)  or  process  variable  change  (△PV),  the  engineering  unit  and  scale  range  of  the  output  value  agree  with  those  of  the  process  variable  (PV).当连接目标是一个功能块并且辅助输出是一个过程变量或者过程变量变化值,输出值的工程单位和量程跟PV一致。
?  When  the  connected  destination  is  a  function  block  and  auxiliary  output  is  the  manipulated  output  value  (MV)  or  manipulated  output  change  (△MV),  the  output  value  is  regarded  as  having  the  same  engineering  unit  and  scale  range  as  those  of  the  manipulated  output  value  (MV).当连接目标是一个功能块而且辅助输出是操作输出值(MV)或操作输出值变化值(△MV),输出值的工程单位和量程跟MV一致。
●  Process  Variable  (PV)过程变量
The  process  variable  (PV)  can  be  output  directly  from  the  input  indicator  blocks.
The  engineering  unit  and  scale  information  of  the  process  variable  (PV)  vary  with  the  connected  destination  of  the  OUT  terminal.  PV可直接从输入指示块中输出。PV的工程单位和量程随着输出端子的连接目标而变化。
?  If  the  connected  destination  is  a  process  I/O,  the  scale  range  and  engineering  unit  of  the  output  value  are  fixed  to  “0  to  100”  and  “%,”  respectively.  However,  this  rule  does  not  apply  if  the  connection  destination  is  a  Fieldbus  block.如果连接目标是一个过程I/O,输出值的工程单位和量程被分别设定为“0到100”和“%”。当连接目标是一个现场总线块时,不采用这个规则。